SYSTEM COMPONENTS AND ACCESSORIES
9418 series fieldbus terminators perform the role of end-of-line resistors for PROFIBUS PA or FOUNDATION™ Fieldbus H1 fieldbuses. Ex i and Ex m versions are available for intrinsically safe FISCO/Entity and non-intrinsically safe (High Power Trunk) fieldbuses. The extremely compact design saves space when installing the terminators in M20 line entrances. They are easy to spot, even when installed.
- “i” version of Zone 1 EOL resistor for FISCO/Entity fieldbuses and “m” version for non-intrinsically safe fieldbuses (High Power Trunk)
- Extremely compact design for installation in M20 line entrances
- For use directly in enclosures or field devices
8 SERIES (35 PRODUCTS)
- Redundant operation of IS1+ I/O modules
- Suitable for I/O modules with non-intrinsically safe I/O from firmware 4.xx
- Simple installation on DIN rail and connection via push-in terminals
- Installation in Zone 2
- For the internal electrical connection between CPU & power module and 8 I/O modules for Zone 1 and Class I, Div. 1 or 16 I/O modules for Zone 2 and Class I, Div. 2
- Redundant data bus, power bus with high availability
- Simple, protected installation in NS35/15 DIN hat rails
- Passive component with redundancy and high availability
- Short delivery times
- Can be used in Zone 1 without acceptance or certification
- For 24 V DC und 120/230 V AC
- Prefabricated and ready for use with entries, bus rails, connection terminals, etc.
- Modifications, add-ons and customer-specific adaptations possible
- Short delivery times
- Can be used in Zone 2 without acceptance or certification
- Prefabricated and ready for use with entries, bus rails, connection terminals, etc.
- Modifications, add-ons and customer-specific adaptations possible
- Communication via PROFIBUS DP, Modbus RTU and Ethernet protocols
- parameterization and configuration of the IS1+ system with connected HART field devices
- automatic topology generation, identification and maintenance, HART live list, condition monitoring
- Diagnostic tool for installations with Modbus RTU (configuration and parameterization) and PROFIBUS DP (error diagnosis)
- test and error diagnosis of IS1+ systems and the connected HART field devices, including without process bus function
- full access to all HART variables
- Ready to install in NEC; CEC Class I, II, Div. 2 and Zone 2 areas
- 316SS NEMA 4X enclosures (based on 8150)
- I/O modules need to be purchase separately
- Ex interface depends on selected I/O modules
- Ready to install in NEC; CEC Class I, Div. 1
- 316SS NEMA 4X enclosures (based on 8150 series)
- I/O modules need to be purchased separately
- Ex interface depends on selected I/O modules